Contact us now to discuss

your data logging requirements

*  info@omniinstruments.co.uk

( +44 (0)8700 43 40 40  

 
 

Request a Quote

click here to send us your enquiry now

 

part of Omni Instruments

Home  |  About Us  |  Terms and Conditions  |  Links  |  Sitemap |  Basket

 

 

Products 

 

Temperature & RH Loggers

 
 

1 & 2 Input Signal Loggers

 
 

4 - 8 Input Compact Loggers

 
 

8 - 48 Input Data Loggers

 
 

Wireless & GSM Loggers

 
 

Web Enabled Data Loggers

 
 

Complete Logging Systems

 
 

Radio and GSM Modems

 
 

Radio Telemetry Systems

 
 

Data Logger Hire

 
 

Enquiry form

If you have any enquiry please fill in the form below and click on submit

name

company name

email

phone

enquiry

enter the characters in the box
CAPTCHA image

 
 
 

4 - 8 Input Compact Loggers \ Eltek Specialist Data Logger Range \ Squirrel 450/850 Series Data Logger

 

1 / 1  

Squirrel 450/850 Series Data Logger

The Squirrel 450/850 series is a cost effective portable data logger with a maximum of 4 or 8 inputs. In common with its bigger brother, the Squirrel 1000 series data logger, the 450 and 850 series are equipped with impressive specifications, long battery life and a three year guarantee. The model 451 and 451 T are universal instruments with configurable inputs for voltage, current and temperature for both thermocouple and thermistor sensors. The model 851 is the 8 input version of the 451.
 
 
 
 

Product details

 

The current 450/850 series consists of the following models, each offers a wide variety of user applications:

Model Inputs Features
451
851
4 channels
8 channels
Each channel configurable for temperature, voltage or current input
451T 4 channels 0.1sec Interval (Fast Recording feature)
451pH 4 channels Supports up to 2 x external pH adaptor module type pH IFU(purchased separately).
451MC 4 channels PCMCIA memory slot installed to accept SRAM card (purchase separately)
452 4 Pulse only channels See CPU module
453 1 Event + 8 Pulse inputs (5Hz) for slow counting  
401 4 channels 'Blind' 451 - less display and control panel

Factory installed Options

Pulse input
The 451/851 only is available with:

  • Two pulse inputs

pH adaptor module type (pH IFU )

  • For use only with the 451MC

PCMCIA Card Slot

As an option, the data logger can be fitted with a slot for an SRAM memory card. The data logger can record directly onto the card or the user can copy the internal memory to the card for easy transfer of the data to a computer equipped with a PC card slot. SRAM cards are available for storing up to 2M readings. Darca Software includes tools for setting up the card and transferring the data from the card to a file suitable for analysis or translation to ASCII format using any of the standard software.

We recommend using King Max, Panasonic or Mitsubishi cards as these have the lowest power consumption. Note: we have found that not all SRAM cards are suitable, particularly those with rechargeable batteries and that some older versions have unacceptably high power consumption when used with Squirrel - especially when battery powered. Refer to Accessories for the SRAM details.

Field installed options

The memory can be expanded to 2M readings (about 2,080,000). Don't forget that a lot of memory takes time to download and that it is possible to reduce the amount of memory used for a logging run. Eltek loggers now download at 38400 baud, and in practice this is about 500 readings per second.

Common Features

All models feature panel mounted controls (except the 401) and a 2 line, 32 character LCD readout for setting up, monitoring and reading recorded events on the logger. Resolution is 12 bit with standard thermistor, thermocouple and DC voltage or current inputs. Two sensor power outputs are available to power external sensors - such as humidity probes.

EU Range
In addition "EU" range is standard, enabling the logger to independently rescale each input to a user defined engineering unit, e.g. humidity can be displayed as 0 to 100% RH, permitting quick and unambiguous understanding of the readings on the display.

Internal memory
The logger is fitted as standard with 250K of memory, backed up by a lithium battery, and at least 250,000 locations are available for data storage. Note that this refers to data storage, not bytes, as 2 bytes of conventional memory are used for every reading. Larger memory can be field fitted by a competent engineer as an option.

Accessories

The Squirrel 450/850 series shares many of the accessories available to the Squirrel 1000 series datalogger. The most significant exceptions are noted.

Software

The 450/850 series is fully compatible with the Eltek Darca Lite and Darca Plus software, providing comprehensive remote control, data transfer and analysis tools using a Windows based PC.

Connection to the PC can be:

  • Direct - use the LC68 computer cable.
  • Remote - via a landline - use a commercially available modem (use only Darca Plus software).
  • Remote - via a cellular network - use the GSM modem kit type GSM-mdm c/w antenna.
  • Remote - via Ethernet - for networked Squirrel dataloggers use the Moxa De311 serial to ethernet convertor.
  • Specification

    Accuracy (at 20ºC) Voltage/Current:
    Temperature:
    ±0.1% of reading ±0.1% of span
    ±0.1% of reading ±0.1% of span
    Environment Ambient temperature: -30ºC to 65ºC
    Humidity up to 95% (non condensing)
    Power Supplies Internal: Six AA manganese alkaline batteries (9V nominal)
    External: 9-14V DC at 100mA.
    Battery Life At least 6 months with all channels recording every 5 minutes
    Clock Accuracy 1 second/day at 20ºC
    Physical details Dimensions (mm): H 120, W 180, D 62
    Weight, inc batteries: Approximately 1Kg
    Material: ABS coated with durable NEXTEL finish
    Interface RS232C at up to 38,400 Baud
    Connectors RS232 Output:
    Inputs:
    6 pin female mini-DIN
    3 pin ST Plug (5mm pitch "screw Terminal")
    Input impedance Voltage and Thermocouple: 1M Ohms
    Current: 10 Ohms
    Sensor power outputs Internally selectable to 5V regulated or Squirrel supply voltage.

    Ranges

    Input typeAvailable rangesResolution
    Thermistor -50 to 150ºC 0.1C
    Thermocouple - Type K 0 to 900ºC 0.5C
    Thermocouple - Type K -200 to 450ºC 0.2C
    Thermocouple - Type T -200 to 350ºC 0.2C
    Voltage 0 to 50mV 50µV
    0 to 100mV 50µV
    0 to 200mV 50µV
    0 to 500mV 0.5mV
    0 to 1V 0.5mV
    0 to 2V 0.5mV
    0 to 5V 5mV
    0 to 10V 5mV
    0 to 20V 5mV
    -25 to 25mV 50µV
    -50 to 50mV 50µV
    -100 to100mV 50µV
    -250 to 250mV 0.5mV
    -500 to 500mV 0.5mV
    -1 to 1V 0.5mV
    -2.5 to 2.5V 5mV
    -5 to 5V 5mV
    -10 to 10V 5mV
    Current 4 to 20mA 0.05%
    0 to 20mA 5µA
     

    Components / Downloads

     
    For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
     

    ref

    description

    downloads

    price(£)

    Order Item

    851

    8 Channels. Universal inputs each V/C, thermistor or thermocouple ( max 1Hz)

     

    Data sheet

     

    750.00

     

    or call us for a quote

    451

    4 Channels. Universal inputs each V/C, thermistor or thermocouple ( max 1Hz)

     

    565.00

     

    or call us for a quote

    Darca Software

    Windows software for Eltek Data Loggers

     

    165.00

     

    or call us for a quote

     
     
     

     Tel +44 (0)8700 43 40 40  Fax +44 (0)8700 43 40 45 info@omniinstruments.co.uk        Tel +1-866-849-3441  Fax +1-866-628-8055  info@omniinstruments.net 

      Tel +61 (0)282 442 363  Fax +61 (0)294 751 278  info@omniinstruments.com.au